Setup / settings

The default display language for solar inverters leaving the Delta factory is set to Eng-
lish.
After connecting to correct DC voltage and running through self-test, you will be asked
to specify the network ID and to select the desired country (see
Country settings", page
The selection has to be confirmed another time by the user. Once confirmed, the net-
work ID and the country selection are stored to the controller memory – and the solar
inverter is ready for operation.
nOTE
Please note that the enter keys on the display are locked, if there is no
input entry within 5 minutes. The following display message appears:
"Block selection". To unlock the enter keys, you need to switch off the
DC voltage and then switch it on again (see
page
1) In certain states in Australia, power limitation is required.
With power limitation, the output (AC) power of SOLIVIA 2.5 AP G3 TR will be as followed :
Power limitation setting AU PL -> Max. power: 2490 W
To activate power limitation, please select dedicated country "Australia PL" (Installed settings are password protected):
Select unit ID =
[1] & press <ENTER> key
Select country =
[Australia PL] & press <ENTER> key
Confirm country selection by pressing <ENTER> key
One of the following labels that are enclosed in the box of the inverter MUST be sticked next to the model label:
For Australia PL
This product has been power limited
at maximal output power of: 2.49kW
To check if power limitation has been activated, please go to the menu S (Setup) and press the „UP" or „DOWN" buttons to
find the following display message:
Down
Up
S -> Country Set
AU L
Down
Up
Operation and installation manual SOLIVIA 2.5 AP G3 TR
30) (countries available: India, Australia, Australia PL
32).
Australia Limitation
„8.3.7.2 Submenu S:
).
1)
„9.2 Display messages",