Delta SOLIVIA 2.5 AP G3 TR Operation And Installation Manual page 37

Table of Contents

Advertisement

MECHAnICAL
DESIGn
Size (L x W x D)
Weight
Cooling
AC connector
DC connector
Communication
interfaces
Display
STAnDARDS /
DIRECTIVES
Protection degree
Safety class
Configurable trip
parameters
Insulation
monitoring
Overload behavior
Anti-islanding
protection /
Grid regulation
EMC
Safety
Operation and installation manual SOLIVIA 2.5 AP G3 TR
AuSTRALIA
AuSTRALIA
Current limitation; power limitation
AS 4777.2; AS 4777.3; IEC 60255.5
AS 4777.1; AS 4777.2; AS 4777.3;
EN 61000-6-2; IEC / EN 61000-6-3
AS/NZS 60950; AS/NZS 3100;
AS 4777.2; AS 4777.3
InDIA
410 x 410 x 180 mm
21.5 kg
Convection
Wieland RST25i3S
4 pairs of Multi-Contact MC4
2 x RJ45 / RS485
3 LEDs, 2-line LCD
InDIA
IP65
I
Yes
Yes
VDE 0126-1-1
IEC / EN 61000-6-2;
IEC / EN 61000-6-3
IEC 62103; EN 50178;
IEC 62109-1, IEC 62109-2
EN
35