In order to connect the device electrically, the following procedures must be followed:
1. DC connection: First, connect the PV module strings to the DC disconnector (not included in
the scope of delivery).
2. Connect the DC disconnector to the solar inverter (ensure correct polarity).
3. AC connection: Please install the Wieland AC mating connector to the AC output cable and then
put the AC connector to the solar inverter. Please make sure, that the sleeve nut is properly
fi xed and tighten.
4. Before switching on the power, check all feeders and connections one last time.
5. Close the DC disconnector.
6. Close the circuit breaker on the AC output side.
7. In case of suffi cient PV voltage (UPV > 150 V), the device now goes into the start-up mode.
8. In case of a new installation the time and date have to be set in sub-menu S (Setup) (see § 7.3.7).
All unoccupied connectors and interfaces must be sealed using the provided sealing
plugs.
6.10

Setup / settings

The default display language for solar inverters leaving the Delta factory is set to English.
After connecting to correct DC voltage and running through self-test, you will be asked to specify
the network ID and to select the desired country (see § 7.3.7.2) (countries available: Australia,
Australia PL
, China, India, Korea and Taiwan).
1)
The selection has to be confi rmed another time by the user. Once confi rmed, the network ID and
the country selection are stored to the controller memory – and the solar inverter is ready for
operation.
Please note that the enter keys on the display are locked, if there is no input entry within 5
minutes. To unlock the enter keys, you need to switch off the DC voltage and then switch it on
again.
1) In certain states in Australia, power limitation is required.
With power limitation, the output (AC) power of SOLIVIA 2.5 AP G3 will be as followed :
Max power:
Nominal power: 2350 W
To activate power limitation, please select dedicated country "Australia PL" (Installed settings are password
protected):
Select unit ID = [1] & press <ENTER> key
Select country = [Australia PL] & press <ENTER> key
Confi rm country selection by pressing <ENTER> key
The following label that is enclosed in the box of the inverter MUST be sticked next to the model label:
For Australia PL
This product has been power limited
at maximal output power of: 2.49kW
To check if power limitation has been activated, please go to the menu S (Setup) and press the „UP" or
„DOWN" buttons to fi nd the following display message:
Down
S -> Country Set
AU L
Down
16
2490 W
Up
AUstralia Limitation