Siemens MICROMASTER 440 Operating Instructions Manual page 7

0,12 kw - 250 kw
Hide thumbs Also See for MICROMASTER 440:
Table of Contents

Advertisement

Issue 10/06
Input voltage range
(with built in Class A Filter)
Order No.
Frame Size
Output Rating(CT)
Output Power
CT Input Current 1)
CT-Output Current
VT Input Current 1)
VT-Output Current
Fuse
Recommended
For UL specified
Input Cable, min.
Input Cable, max.
Output Cable, min.
Output Cable, max.
Weight
Tightening torques for
power terminals
1) Secondary conditions:
*
UL listed fuses such as Class NON from Bussmann are required for use in America
MICROMASTER 440
Operating Instructions (Compact)
3 AC 200 V – 240 V. ± 10 %
6SE6440-
2AC23-
2AC24-
0CA1
0CA1
C
3,0
4,0
[kW]
4,0
5,0
[hp]
6,0
7,7
[kVA]
15,6
19,7
[A]
13,6
17,5
[A]
-
28,3
[A]
-
22,0
[A]
25
32
[A]
3810
3812
3NA
*
*
2
2,5
4,0
[mm
]
14
12
[AWG]
2
10,0
10,0
[mm
]
8
8
[AWG]
2
1,5
4,0
[mm
]
16
12
[AWG]
2
10,0
10,0
[mm
]
8
8
[AWG]
5,7
5,7
[kg]
12,5
12,5
[lbs]
2,25
[Nm]
(20)
[lbf.in]
Input current at the rated operating point - applies for the short-circuit voltage of the line
supply V
= 2 % referred to the rated drive converter power and a rated line supply voltage
k
of 240 V without line commutating reactor.
2AC25-
5CA1
5,5
7,5
9,6
26,5
22,0
34,2
28,0
35
3814
*
4,0
12
10,0
8
4,0
12
10,0
8
5,7
12,5
2 Electrical Installation