Issue 10/06
PID cancer control
Closed-loop dancer roll control is selected with P2251 = P2200 = 1. Important parameters
and the structure are shown in the following diagrams.
MOP
ADC
FF
USS
BOP link
USS
COM link
CB
COM link
ADC2
Parameter
P1070
P2200
P2251
P2253
P2264
MICROMASTER 440
Operating Instructions (Compact)
P1070
SUM
AFM
P1075
P2254
PID
PID
P2253
SUM
RFG
PID
P2264
PT1
P2265
P2200
Parameter text
CI: Main setpoint
BI: Enable PID controller
PID mode
CI: PID setpoint
CI: PID feedback
RFG
0
PID
PID
PT1
PID
Output
PID
PID
SCL
P2271
Setting
Meaning
1024
Fixed setpoint (FF)
1050
MOP
755.0
Analog input 1
2015.1
USS on BOP link
2019.1
USS on COM link
2050.1
CB on COM link
0
PID controller de-activated
1.0
PID controller always active
722.x
Digital input x
BICO
BICO parameter
1
PID as trim
1024
Fixed setpoint (FF)
1050
MOP
755.0
Analog input 1
2015.1
USS on BOP link
2019.1
USS on COM link
2050.1
CB on COM link
755.0
Analog input 1
755.1
Analog input 2
6 Commissioning
0
Motor
control
1
&
P2251
= 1
65