Siemens MICROMASTER 440 Operating Instructions Manual page 10

0,12 kw - 250 kw
Hide thumbs Also See for MICROMASTER 440:
Table of Contents

Advertisement

2 Electrical Installation
Input voltage range
Order No.
6SE6440- 2UD13
Frame Size
Output Rating(CT)
Output Power
CT-Input Current 1)
CT-Output Current
VT-Input Current 1)
VT-Output Current
Fuse
Recommended
For UL specified
Input Cable, min.
Input Cable, max.
Output Cable, min.
Output Cable, max.
Weight
Tightening torques for
power terminals
Order No.
6SE6440- 2UD31
Frame Size
Output Rating(CT)
Output Power
CT-Input Current 1)
CT-Output Current
VT-Input Current 1)
VT-Output Current
Fuse
Recommended
For UL specified
Input Cable, min.
Input Cable, max.
Output Cable, min.
Output Cable, max.
Weight
Tightening torques for
power terminals
1) Secondary conditions:
*
UL listed fuses such as Class NON from Bussmann are required for use in America
10
3 AC 380 V – 480 V. ± 10 %
2UD15
-7AA1
-5AA1
0,37
0,55
[kW]
0,5
0,75
[hp]
0,9
1,2
[kVA]
2,2
2,8
[A]
1,3
1,7
[A]
-
-
[A]
-
-
[A]
10
10
[A]
3803
3803
3NA
*
*
2
1,0
1,0
[mm
]
18
18
[AWG]
2
2,5
2,5
[mm
]
14
14
[AWG]
2
1,0
1,0
[mm
]
18
18
[AWG]
2
2,5
2,5
[mm
]
14
14
[AWG]
1,3
1,3
[kg]
2,9
2,9
[lbs]
[Nm]
[lbf.in]
2UD31
2UD31
-1CA1
-5DA1
C
11,0
15,0
[kW]
15,0
20,0
[hp]
19,8
24,4
[kVA]
23,1
33,8
[A]
26,0
32,0
[A]
33,8
37,0
[A]
32,0
38,0
[A]
35
50
[A]
3814
3820
3822
3NA
*
1817-0 1818-0 1820-0 1021-0 1022-0 1224-0 1225-0 1227-0
3NE
2
6,0
10,0
[mm
]
10
8
[AWG]
2
10,0
35,0
[mm
]
8
2
[AWG]
2
6,0
10,0
[mm
]
10
8
[AWG]
2
10,0
35,0
[mm
]
8
2
[AWG]
5,5
16,0
[kg]
12,1
35,0
[lbs]
2,25
[Nm]
[lbf.in]
(20)
Input current at the rated operating point - applies for the short-circuit voltage of the line
supply V
= 2 % referred to the rated drive converter power and a rated line supply voltage
k
of 400 V without line commutating reactor.
2UD17
2UD21
2UD21
2UD22
-5AA1
-1AA1
-5AA1
A
0,75
1,1
1,5
1,0
1,5
2,0
1,6
2,3
3,0
3,7
4,9
5,9
2,2
3,1
4,1
-
-
-
-
-
-
10
10
10
3803
3803
3803
*
*
*
1,0
1,0
1,0
18
18
18
2,5
2,5
2,5
14
14
14
1,0
1,0
1,0
18
18
18
2,5
2,5
2,5
14
14
14
1,3
1,3
1,3
2,9
2,9
2,9
1,1
(10)
2UD32
2UD33
2UD33
-8DA1
-2DA1
-0EA1
-7EA1
D
E
18,5
22,0
30,0
25,0
30,0
40,0
29,0
34,3
47,3
37,0
43,0
59,0
38,0
45,0
62,0
43,0
59,0
72,0
45,0
62,0
75,0
63
80
100
3824
3830
3832
10,0
16,0
25,0
8
6
3
35,0
35,0
35,0
2
2
2
10,0
16,0
25,0
8
6
3
35,0
35,0
35,0
2
2
2
16,0
16,0
20,0
35,0
35,0
44,0
10
(89)
Issue 10/06
2UD23
2UD24
2UD25
-2BA1
-0BA1
-0BA1
-5CA1
B
2,2
3,0
4,0
3,0
4,0
5,0
4,5
5,9
7,8
7,5
10,0
12,8
5,9
7,7
10,2
-
-
-
-
-
-
16
16
20
3805
3805
3807
*
*
*
1,5
1,5
2,5
16
16
14
6,0
6,0
6,0
10
10
10
1,0
1,0
1,0
18
18
18
6,0
6,0
6,0
10
10
10
3,3
3,3
3,3
7,3
7,3
7,3
1,5
(13,3)
2UD34
2UD35
2UD37
-5FA1
-5FA1
-5FA1
F
37,0
45,0
55,0
50,0
60,0
75,0
100,0
57,2
68,6
83,8
110,5
72,0
87,0
104,0
139,0
75,0
90,0
110,0
145,0
87,0
104,0
139,0
169,0
90,0
110,0
145,0
178,0
125
160
200
3836
3140
3144
25,0
35,0
70,0
3
2
2/0
35,0
150,0
150,0
150,0
2
300
300
25,0
35,0
70,0
3
2
2/0
35,0
150,0
150,0
150,0
2
300
300
20,0
56,0
56,0
44,0
123,0
123,0
123,0
50
(445)
MICROMASTER 440
Operating Instructions (Compact)
(Unfiltered)
2UD27
-5CA1
C
5,5
7,5
7,5
10,0
10,1
14,0
15,6
22,0
13,2
19,0
17,3
23,1
19,0
26,0
20
32
3807
3812
*
*
2,5
4,0
14
12
10,0
10,0
8
8
2,5
4,0
14
12
10,0
10,0
8
8
5,5
5,5
12,1
12,1
2,25
(20)
75,0
250
95,0
3/0
300
95,0
3/0
300
56,0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: