5.3 Communication Time

The Model V700 Series has two communication times: the transmission time and
the TAT (Turn Around Time).

(1) Transmission Time

This is the transmission processing time between the Reader Writer and the
Tags. This time varies in accordance with the number of pages to be read /
written.
The transmission time values are as indicated below. This value is estimated
based on the assumption that the transmission operation is on trigger mode
and that there is no interference in transmission due to noise and other
causes.
Transmission Time
(ms)
Total pages processed

(2) TAT

This is the time required for the high-end unit to transmit a command to the
Reader Writer, and to complete receipt of a response. This time varies in
accordance with the transmission speed and the communication control mode.
Command
<Example of TAT Calculation>
• Read 1 page
Command
010000000004[CR]
( )
(
)
1
×
×
sec
11
bits
9600
(bit time) (number of bits per character) (number of characters transmitted)
Prerequisites: 1 HEX code specification
2 No spaces between characters; all data sent consecutively
Write
Read
Transmission time
TAT
Transmission time
(
)
(
)
+
13
characters
114
m
sec
Transmission Time Calculation Formula
Transmission Time (msec)
Read
T=48N+66
Write
T=55N+120
N: pages to be processed