(4) Byte Write

The Byte Write command is used when data is to be written onto the Tag in
unit of Bytes. Data of any bytes can be written from the specified address. An
area spanning over more than one page may be specified, but a maximum
limit of 16 pages applies.
n Command
The area's leading address and the data to be written as parameters will be
transmitted. The address may be specified within the range of 00h ~ EFh. The
data to be written is to be specified in ascending order from the specified address.
Designated
Command
Option
Address
"0"
"4"
* Data number n = number of bytes to be written (2 characters each for HEX
code, one character each for ASCII code.)
n Response
The completion code ("00" when normal) will be transmitted.
Completion
code
"0"
"0"
Data to be written*
(Data 1)
Terminator
CR
Terminator
⋅ ⋅ ⋅
CR
(Data n)