(3) Multiple Write

The Multiple Write command is used when the same data is written in units of
pages. Pages may be specified at random. There is no limit on the number of
pages that may be written at one time.
n Command
The designated pages to be written as parameters and the data to be written onto
each page is transmitted. Page specifications shall be made by specifying the bit
indicating the page as "1" and the other bytes as "0". This binary is converted to a
hexadecimal and transmitted as a command. Data to be written should be
specified in the order of specification of the designated pages.
Command
Option
"0"
"3"
Bit
7
6
5
Page 30 29 28
~
Value
"00" ~ "FF"
* Data number n = 8 (2 characters each in Hex code, one character each in
ASCII code)
** 0, 1 bits should be specified as "0". When "1" is specified, it will be regarded
as an error (error code 14).
n Response
The completion code ("00" when successful) will be transmitted.
Completion
code
"0"
"0"
Page specification
1
0
7
6
1
24 23 22 21
~
16 15 14 13
"00" ~ "FF"
Terminator
CR
Data to be written*
(Data 1)
0
7
6
1
0
~
8
7
"00" ~ "FF"
(18/30)
(Data n)
⋅ ⋅ ⋅
CR
7
6
2
1
0
6
5
~
1
** **
"00" ~ "FC"

Hide quick links: