Locations and Functions of Parts
6 ALARM IN and control terminals
The C terminals are for ground.
C
1
2
3
1 to 6 terminals
Connect alarm sensors to receive external alarm
signals.
For details, see "Connecting external alarm sensors" on
page 53.
ALARM RESET terminal
Alarm reset input (normally-open contact)
ALARM FULL terminal (5V DC/5.7 kΩ)
The output level drops to 0 V if the remaining capacity
of the alarm recording area of the built-in hard disk
drops below the specified value.
7 Control terminals
For input and output of various control signals.
The C terminals are for ground.
CLOCK
C R1 R2 IN OUT
R1/R2 terminals (resistor-alley system)
For remote control.
For the connections, see "Connections for Remote Control"
on page 56.
CLOCK terminals
You may adjust the built-in clock using an external
switch or synchronize the clocks of other connected
devices to the clock of this unit.
IN: Clock input (normally-open contact). Connect an
external switch or equivalent.
OUT: Clock output (5V DC/5.7 kΩ). The output level
drops to 0 V at the time you specified by menu
operation.
For the connection, see "Clock Adjustment" on page 57.
12
ALARM
RESET FULL
4
5
6
C
NON REC
EXT TIMER
WARNING
NC
FULL
C
NON REC terminal (5V DC/5.7 kΩ)
The output level drops to 0 V if recording is
interrupted.
WARNING terminal (5V DC/5.7 kΩ)
The output level drops to 0 V if any problem occurs
with the HDD.
FULL terminal (5V DC/5.7 kΩ)
The output level drops to 0 V if the remaining capacity
of the normal recording area of the built-in hard disk
drops below the specified value (default: 1%).
EXT TIMER terminal
When External Timer Recording mode has been
specified, recording starts upon reception of a signal at
this terminal (normally-open contact).
8 -AC IN connector
Connect AC power using the supplied AC power cord.
9 Power cord holder
Secure the AC power cord using the supplied tie, as
shown below.
0 LAN connector (10Base-T/100Base-TX)
Used to control this unit via a network.
qa ALL RESET button
For reset or reboot of the HSR-X206/X206P.