Commissioning

7.1

Prerequisites

For commissioning, you need a PC with the following requirements:
● CPU: DualCore with 3 GHz
● RAM: 4 GB
● Operating system: Microsoft Windows 7 operating system or newer
● .NET Framework V4.0
● Web browser
Tested Web browsers: Microsoft Internet Explorer as of V11, Mozilla Firefox as of V52
and Google Chrome as of V57
● Recommended screen resolution: 1920 × 1080
● Network connection via Ethernet TCP/IP
● Optional: Primary Setup Tool (PST)
You can find the Primary Setup Tool (PST) in your SIMATIC installation or as a free
download on the pages of the Siemens Industry Online Support
(https://support.industry.siemens.com/cs/ww/en/view/19440762).
7.2

Connecting using the "CONNECT" button

Follow the steps below to connect the optical reader and establish the connection using the
"CONNECT" button:
1. Connect the power supply cable to the combination interface and the Ethernet cable
directly (without a switch) to the Ethernet interface of the PC.
2. Wait until the "CONNECT" LED goes out.
3. Press the "CONNECT" button.
4. Wait until the "CONNECT" LED is continuously lit.
5. Open your Internet browser, enter "MV500" and confirm your entry by pressing the
<Enter> key.
SIMATIC MV500
Operating Instructions, 06/2018, C79000-G8976-C494-01
7
87