Table 10- 11 Diagnostic information of SFB 52 "RDREC"
Byte
Value
0 ... 1
W#16#0010
2 ... 3
W#16#0012
4 ... 5
W#16#0100
6 ... 7
W#16#0000
8 ... 9
W#16#0000
10 ... 11
W#16#0000
12
B#16#08 / B#16#10
13
B#16#05
14 ... 15
W#16#0004
16 ... 17
W#16#0000
18 ... 19
W#16#0805 / W#16#1005
20 ... 21
See value with the section "Error
messages (Page 176)"
10.2

Maintenance and repair

Maintenance
The devices are maintenance-free. Cleaning is usually not necessary.
If the protective lens barrel becomes dirty, we recommend that you clean it professionally in
order to achieve a consistent reading performance.
Repair
For repairs, send the optical reader to Siemens without its protective lens barrel, lighting unit,
and other accessories. The current contact details are available via the Siemens Industry
Online Support.
SIMATIC MV500
Operating Instructions, 06/2018, C79000-G8976-C494-01
Meaning
Data record type: Diagnostics data record
Data record length starting at byte 4: 18 bytes
Version
Slot
Subslot
Channel
Error occurred / no error occurred
Identifier indicating that all variables are stored in words starting at byte
14.
ID for vendor-specific diagnostics (fixed)
Channel number
Content identical to that of bytes 12 and 13.
ID of the error that occurred.
Service and maintenance