Section 1
General Information
Other Analog Input:
Full Scale Range
Resolution
Update Rate

Analog Outputs:

Analog Outputs
Full Scale Range
Source Current
Resolution
Update Rate

Digital Inputs:

Opto-isolated Logic Inputs
Rated Voltage
Input Impedance
Leakage Current
Update Rate

Digital Outputs:

Opto-isolated Logic Outputs
ON Current Sink
ON Voltage Drop
Update Rate
Maximum Voltage
MN722
0 - 10 VDC
9 bits + sign
500 sec
2 Assignable
0 - 5 VDC
1 mA maximum
8 bits
2.0 msec
9 Assignable
10 - 30 VDC (closed contacts std)
6.8 K Ohms
10 A maximum
16 msec
4 Assignable
50 mA Max
2 VDC Max
33 msec
30 VDC
Specifications, Ratings & Dimensions 7-3