15 Speed 2-Wire Mode Connections

Table 3-9 Switch Truth Table for 15 Speed, 2 Wire Control Mode
3-30 Receiving & Installation
Switch Truth Table is defined in Table 3-9.
Operation in the 15 Speed 2-Wire mode is controlled by the Opto Isolated inputs at J1-8
through J1-16. The Opto inputs can be switches as shown in Figure 3-13 or logic signals
from another device. The External Trip Opto Input at J1-16 is active if connected as
shown and the Level 2 Protection block, External Trip parameter is set to ON.
Switched inputs at J1-11 through J1-14 allow selection of 15 preset speeds and provide
Fault Reset as defined in Table 3-9.
Function
J1-11
Preset 1
Open
Preset 2
Closed Open
Preset 3
Open
Preset 4
Closed Closed Open
Preset 5
Open
Preset 6
Closed Open
Preset 7
Open
Preset 8
Closed Closed Closed Open
Preset 9
Open
Preset 10
Closed Open
Preset 11
Open
Preset 12
Closed Closed Open
Preset 13
Open
Preset 14
Closed Open
Preset 15
Open
Fault Reset
Closed Closed Closed Closed
J1-12
J1-13
J1-14
Open
Open
Open
Open
Open
Closed Open
Open
Open
Open
Closed Open
Closed Open
Closed Closed Open
Open
Open
Closed
Open
Closed
Closed Open
Closed
Closed
Open
Closed Closed
Closed Closed
Closed Closed Closed