4.7.4.6

Printenvs Command

The printenvs command prints the current value of each OpenBoot Diagnostics
configuration variable.
CODE EXAMPLE 4-13
obdiag> printenvs
test-args = null
diag-switch? = false
diag-passes = 1
diag-level = max
Hit any key to return to the main menu
4.7.4.7

Setenv Command

The setenv command allows the user to change the variable settings of OpenBoot
Diagnostics. The OpenBoot Diagnostics then verifies that the new value is valid and
echoes the new value to the user.
CODE EXAMPLE 4-14
obdiag> setenv diag-switch? true
diag-switch? = true
Hit any key to return to the main menu
4.7.4.8

Exit Command

The exit command returns the user to the ok prompt and relinquishes control
back to OpenBoot PROM.
CODE EXAMPLE 4-15
obdiag> exit
ok
4-16