4.3

Faults history and the list of fault displays

For details, refer to the FR-F800 Instruction Manual (Detailed).
Operation
panel
indication
LOCD
Password locked
Er1 to Er4
Parameter write error
Er8
rE1 to rE4
Copy operation error
rE6 to rE8
Err.
Error
OL
Stall prevention (overcurrent)
oL
Stall prevention (overvoltage)
TH
Electronic thermal relay function pre-alarm
PS
PU stop
MT1 to
Maintenance signal output
MT3
CF
Continuous operation during communication fault
SA
Safety stop
UF
USB host error
ED
Emergency drive in operation
LDF
Load fault warning
EHR
Ethernet communication fault
FN
Fan alarm
FN2
Internal-circulation fan alarm
E.OC1
Overcurrent trip during acceleration
E.OC2
Overcurrent trip during constant speed
E.OC3
Overcurrent trip during deceleration or stop
E.OV1
Regenerative overvoltage trip during acceleration
Regenerative overvoltage trip during constant
E.OV2
speed
Regenerative overvoltage trip during deceleration
E.OV3
or stop
Inverter overload trip (electronic thermal relay
E.THT
function)
Motor overload trip (electronic thermal relay
E.THM
function)
E.FIN
Heatsink overheat
E.IPF
Instantaneous power failure
E.UVT
Undervoltage
E.ILF
Input phase loss
E.OLT
Stall prevention stop
E.GF
Output side earth (ground) fault overcurrent
E. SOT
Loss of synchronism detection
E.LUP
Upper limit fault detection
E.LDN
Lower limit fault detection
E.LF
Output phase loss
E.OHT
External thermal relay operation
E.PTC
PTC thermistor operation
E.OPT
Option fault
E.OP1
Communication option fault
E. 1 to E. 3 Option fault
E.PE
Parameter storage device fault
E.PUE
PU disconnection
E.RET
Retry count excess
E.PE2
Parameter storage device fault
E. 5 to E. 7
CPU fault
E.CPU
E.CTE
Operation panel power supply short circuit
E.P24
24 VDC power fault
E.CDO
Abnormal output current detection
E.IOH
Inrush current limit circuit fault
E.AIE
Analog input fault
E.OS
Overspeed occurrence
E.BE
Brake transistor alarm detection
Name
Faults history and the list of fault displays
Operation
panel
indication
E.USB
USB communication fault
E.13
Internal circuit fault
E.PBT
E.SAF
Safety circuit fault
E.IAH
Abnormal internal temperature
E.LCI
4 mA input fault
E.PCH
Pre-charge fault
E.PID
PID signal fault
E.EHR
Ethernet communication fault
E.16 to
User definition error by the PLC function
E.20
If faults other than the above appear, contact your sales