Finalizing the Installation
Packing List
Propane Conversion Kit (2 orifices, pilot orifice)
Wall Thimble
Additional Items Required
Log Set
Direct Vent
Gas Line Equipment (shutoff valve, pipe, etc.)
Electrical Equipment (min. 14 gauge, grounded line)
Installation Overview
All requirements below must be met.
See the section
"Mantel Requirements"
See "Optional Non-
Combustible Facing"
Recommended Installation Procedure
Frame the opening for the fireplace. Make sure to allow for vent installation.
This fireplace is designed to accommodate 1/2" (13mm) or 5/8" (16mm) drywall (see "Nailing
Brackets" on page 15 for details). Secure the fireplace to the framing.
Install the vent, gas line and electrical hook-up.
Install the drywall.
Install the hearth (if applicable).
Install the facing (if applicable).
Install the mantel (if applicable).
Finalize the installation (see page 34).
© Travis Industries
Drywall
Drywall
Side
1" Min.
Wall
25mm
See "Optional Non-
Combustible Hearth"
See the section
"Electrical Connection"
7/18/2018 - 1481
(for qualified installers only)
Remote Control
Embers, Rock Wool, EmberBed Glass
See the section
"Vent Requirements"
See the section
"Approved Vent
Configurations"
Insulation must not fill
the 1/2" (13mm)
clearance around the
back and sides of the
fireplace.
Nailing Brackets
See the section "Minimum
Framing Dimensions"
See the section
"Gas Line Installation"
7
864 40K CF