Outdoor Fireplace Installations

Travis Industries Inc. gas-fired fireplaces are
suitable for installation into outdoor areas
protected from direct water impingement. In
addition to maintaining listed mantel and
combustibles clearances, a rain protection
overhang factor of 1/2 shall be constructed to
the front and to each side of installed
appliances (see the illustration to the right). All
wiring connections to line power shall be in
accordance with outdoor requirements of
NECA NFPA 70.
© Travis Industries
(for qualified installers only)
Side of
Fireplace
The overhang (A) must extend at least 1/2 the roofline height
(B). Height is measured from the base of the fireplace.
For example: if the rooline (B) is 8' above the base of the
fireplace, the overhang (A) must be at least 4'.