Electrical System Data - Carrier 69NT40-561-399 Operation And Service Manual

Container refrigeration units
Table of Contents

Advertisement

3.3

ELECTRICAL SYSTEM DATA

Circuit Breaker
Compressor Motor
Condenser Fan Motor
Evaporator Coil Heaters
Evaporator Fan Motors
Fuses
Vent Position Sensor (VPS)
Solenoid Valve Coils (ESV/
USV) 24 VAC
DLV Coil 12 VDC
CB-1 (25 amp)
CB-2 (50 amp)
CB-3 (70 amp)
Full Load Amps (FLA)
Full
Load
Amps,
High
Speed
Full Load Amps, Low Speed
RPM, High Speed
RPM, Low Speed
Voltage and Frequency
Bearing Lubrication
Rotation
Number of Heaters
Rating
Resistance (cold)
Type
Full Load Amps
High Speed
Full Load Amps
Low Speed
Rotations Per Minute
High Speed
Rotations Per Minute
Low Speed
Voltage and Frequency
Bearing Lubrication
Rotation
Control Circuit
Controller/DataCORDER
Emergency Bypass
Electrical Output
Supply Voltage
Supply Current
Nominal
Resistance
77°F (25°C)
Maximum Current Draw
Nominal
Resistance
68°F (20°C)
3–7
Trips at 29 amps
Trips at 62.5 amps
Trips at 87.5 amps
13 amps @ 460 VAC
380 VAC/3 PH/50 Hz
0.73
.42
1425 rpm
720 rpm
360 - 460 VAC +/-2.5Hz
Factory lubricated, additional grease not required.
CW when viewed from shaft end.
750 watts +5/-10% each @ 230 VAC
6.8 to 77.2 ohms @ 20°C (68°F)
380 VAC/3 PH/50 Hz
1.07
0.47
2850 rpm
1425 rpm
360 - 460 VAC +/- 1.25Hz 400 - 500 VAC +/- 1.5Hz
Factory lubricated, additional grease not required
CW when viewed from shaft end
7.5 amps (F3A,F3B)
5 amps (F1 & F2)
10 amps (FEB)
0.5 VDC to 4.5 VDC over 90 degree range
5 VDC +/- 10%
5 mA (typical)
@
7.7 ohms +/- 5%
@
14.8 ohms +/- 5%
460 VAC/3 PH/60 Hz
0.80
.44
1725 rpm
850 rpm
400 - 506 VAC +/-2.5Hz
6
Sheath
460 VAC/3 PH/60 Hz
0.9
0.47
3450 rpm
1725 rpm
0.7 amps
T-365