Module 9112 Transmit Ascii Characters Via Data Interface - HEIDENHAIN iTNC 530 HSCI Technical Manual

Hide thumbs Also See for iTNC 530 HSCI:
Table of Contents

Advertisement

July 2013

Module 9112 Transmit ASCII characters via data interface

You must first assign the interface to the PLC and initialize it with Module
9100. Module 9112 transmits a single ASCII character.
Note
Set MP5030.x = 2 so that the transmitted characters do not disturb the set
protocol procedure.
Define the characters in at least one word so that the values to 255 can be
recognized.
Can only be called in a submit job or spawn job!
Call:
PS
B/W/D/K <>Interface>
0: RS232
1: RS422
PS
W/D/K
<>ASCII code [0 to 255]>
CM
9112
Error code:
Marker
Value
Meaning
M4203
0
Character was transmitted
1
Error code in W1022
W1022
1
Incorrect interface
13
Interface not ready or no connection
14
Interface not assigned
15
Transmit buffer not empty
20
Module was not called in a submit or spawn job
10.10 Data Transfer by PLC
1927

Advertisement

Table of Contents
loading

Table of Contents