Activating existing
NC software
July 2013
Before activating existing NC software, ensure that the free space on the
storage medium of the MC 6xxx is at least 50 % the size of the occupied
space. If that is not the case, you must save the files to a PC, e.g., with the
TNCremoNT data-transfer software for PCs.
While in the Programming and Editing operating mode, press the MOD key.
Enter the code number 95148 and confirm your entry with the ENT key.
While in the Machine-parameter programming mode, press the MOD key.
Press the UPDATE DATA soft key.
The name and path of a log file can be entered after Path = in the header.
Press the BIN → ASC soft key to convert the files on the hard disk from binary
to ASCII format.
Equivalent file name extensions in ASCII and binary format
.H
.H%
.TCH
.TC%
.PNT
.PN%
Press the SELECT soft key.
All NC software versions that exist in the control are shown in the selection
window that appears.
Select the NC software to be activated with the arrow keys and press the
SELECT soft key. The selected NC software is marked with an asterisk (*) in
the Sel column. Confirm your selection with the YES soft key. The control
activates the selected NC software and performs a reset. Press the END
key, the NO soft key or the END soft key to exit the list box without making a
new selection.
If required, complete or delete the machine parameters.
While in the Programming and Editing operating mode, press the MOD key.
Enter the code number 95148 and confirm your entry with the ENT key.
While in the Machine-parameter programming mode, press the MOD key.
Press the UPDATE DATA soft key.
Press the ASC → BIN soft key to convert the files on the hard disk from
ASCII format back to binary format.
The activation of the NC software is completed.
With the COPY SAMPLE FILES soft key, the HEIDENHAIN standard tables for
cutting data, the tilting-axis geometry, and the M-function macros as well as
a prototype for a freely definable table (contains only the column Name) can
be copied into the corresponding directories.
2.7 Software
.I
.I%
.D
.D%
.COM
.CO%
.T
.T%
.P
.P%
.CMA
.CM%