P805 Echo Confidence
Measures echo reliability. It displays the echo confidence of the measurement echo from
the last shot. P804 defines the minimum criterion for echo confidence.
Values (view only)
Related Parameters
Press the measurement key
values.
Both short and long shot Echo Confidence values are displayed.
Display
x : --
-- : y
x : y
E
-- : --
P806 Echo Strength
Displays the absolute strength (in dB above 1 μV rms) of the echo selected as the
measurement echo.
Values (view only)
Press the measurement key
Page 58
SITRANS Probe LU (HART) – OPERATING INSTRUCTIONS
x:y
Format
x = short (range 0 to 99)
y = long (range 0 to 99)
----
(Shot not used)
P804 Confidence Threshold
P830 TVT Type
to get a new reading that will update confidence
short shot confidence value, (long shot not used)
long shot confidence value, (short shot not used)
short and long shot confidence values (both used)
transducer cable is open or short circuited
no shots were processed for Sonic Intelligence evaluation
Display
to get a new reading that will update echo strength.
Description
–20 to 112
A5E32337695