Technical data, dimensional drawings and connection diagrams
Electrical installed load ratings
The following table shows the electrical installed load ratings:
OES
3~ 400V 50/60Hz (3/N/PE)
Rated power consumption
Convection power
Motor power
Rated current
max. permissible system
impedance Z
sys
Fuse
recommended conductor
cross-section*
Heat output
latent
sensible
3~ 230V 50/60Hz (3/PE)
Rated power consumption
Convection power
Motor power
Rated current
max. permissible system
impedance Z
sys
Fuse
recommended conductor
cross-section*
3~ 200V 50/60Hz (3/PE)
Rated power consumption
Convection power
Motor power
Rated current
max. permissible system
impedance Z
sys
Fuse
recommended conductor
cross-section*
*recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.
Installation manual
6.10
6.20
Table-top applian-
ces
[kW]
11,4
19,8
[kW]
10,5
18,9
[kW]
0,8
0,8
[A]
15,3
26,3
[S]
0,627
0,252
[A]
16
35
2
[mm
]
5G4
5G6
[kJ/h]
2100
3500
[kJ/h]
2500
4500
[kW]
11,7
20,1
[kW]
10,5
18,9
[kW]
0,8
0,8
[A]
27,2
46,2
[S]
0,239
0,151
[A]
35
50
2
[mm
]
5G6
5G16
[kW]
11,7
20,1
[kW]
10,5
18,9
[kW]
1,1
1,1
[A]
30,8
52,7
[S]
0,239
0,151
[A]
35
63
2
[mm
]
5G6
5G16
89
10.10
10.20
12.20
Floor-standing
appliances
19,8
34,3
34,3
18,9
33,0
33,0
0,8
1,2
1,2
26,3
47,6
47,6
0,252
0,113
0,113
35
50
50
5G6
5G16
5G16
3500
6400
6900
4500
7800
7800
20,1
34,6
34,6
18,9
33,0
33,0
0,8
1,5
1,5
46,2
83,5
83,5
0,151
-
-
50
100
100
5G16
5G35
5G35
20,1
34,6
34,6
18,9
33,0
33,0
1,1
1,5
1,5
52,7
95,4
95,4
0,151
-
-
63
100
100
5G16
5G35
5G35
20.10
20.20
39,6
68,5
37,8
66,0
1,7
2,4
52,4
95,0
0,125
-
63
100
5G16
5G35
6900
12200
8900
15400
40,1
69,1
37,8
66,0
2,2
3,0
92,3
166,9
-
-
100
200
5G35
5G95
40,1
69,1
37,8
66,0
2,2
3,0
105,2
190,6
-
-
125
200
5G35
5G95