Connecting up the combi steamer
Requirements
Make sure that the following requirements have been met:
The supply flow pressure must be suitable for the appliance. If the measured supply flow pressure
differs from the figures given in the table below, the gas supply company must be notified. The ap-
pliance must not be put into use in this case.
A gas shut-off device must be installed at the customer's premises.
Arrangement using a bank of bottles
To avoid severe icing up of the liquid gas bottles, use a bank of bottles containing at least 2 liquid gas
bottles.
Caution
Protect the flexible gas lines from chemical, thermal and mechanical damage.
The following drawing and table show the construction of the gas installation using liquid gas bottles.
2
1
Item
Description
1
Liquid gas bottle
2
HP flexible tube 0.40 m
3
T connector
4
Pressure regulator
5
Burst pipe protection
6
Flexible gas pipe to appliance max. 2.00 m long
Installation manual
5
4
3
Requirement
designed for gas-phase withdrawal
Medium- or high-pressure pipe
to DIN 4815-1 or DIN3384
Standard design
Standards mark:
Nominal flow rate Qn:
Pressure rating:
Output pressure:
Standard design
63
6
to DIN-DVGW or CE mark
according to appliance size, see table
PN 16
50 mbar