Convotherm OES 6.10 Installation Manual page 100

Combi steamer
Hide thumbs Also See for OES 6.10:
Table of Contents

Advertisement

Technical data, dimensional drawings and connection diagrams
Summary of gas data
The table below lists the possible gas data (as per CE) at 15°C and 1013 mbar dry:
Gas type and symbol
Supply flow pressure
Wobbe Index
lower W
u
upper W
o
Lower heating value
H
u
H
u
Higher heating value
H
o
H
o
*up to 15% higher consumption for butane G30.
Flue gas values
The following table shows the required flue gas values:
CO
2
CO
Flue gas output rate
The following table shows the flue gas output rate for the gas appliances:
Flue gas output rate
Heat rating and heat output of gas appliances
The following table shows the heat rating and heat output for gas appliances:
Rating
Convection burner
Heat output
latent
sensible
Installation manual
2H (E)
Natural gas (H)
G20
[mbar]
17 - 25
45,7
50,7
3
[MJ/m
]
34,0
[MJ/kg]
-
3
[MJ/m
]
37,8
[MJ/kg]
-
Natural gas
[%]
8,6 - 9,6
[ppm]
< 500
6.10
6.20
Table-top applian-
ces
3
[m
/h]
25
40
6.10
6.20
Table-top applian-
ces
[kW]
12
20
[kJ/h]
2100
3500
[kJ/h]
2500
4100
2L (LL)
Natural gas (L)
G25
18 - 30
37,4
41,5
29,3
-
32,5
-
Propane liquid gas
10,0 - 11,0
< 500
10.10
10.20
40
70
10.10
10.20
20
35
3500
7100
4100
7200
99
3B
3P
Butane G30*
Propane G31
25 - 57,5
25 - 57,5
80,6
70,7
87,3
76,8
116,1
88,0
45,7
46,7
125,8
95,7
49,5
50,4
Butane liquid gas
11,7 - 12,7
< 500
12.20
20.10
Floor-standing
appliances
80
80
12.20
20.10
Floor-standing
appliances
40
40
11000
7100
8200
8200
20.20
140
20.20
70
11000
14100