Convotherm OES 6.10 Installation Manual page 104

Combi steamer
Hide thumbs Also See for OES 6.10:
Table of Contents

Advertisement

Technical data, dimensional drawings and connection diagrams
Electrical installed load ratings
The following table shows the electrical installed load ratings:
OGB
3N~ 400V 50/60Hz (3/N/PE)
Rated power consumption
Rated current
Fuse
recommended conductor
cross-section*
3~ 230V 50/60Hz (3/PE)
Rated power consumption
Rated current
Fuse
recommended conductor
cross-section*
*recommended conductor cross-section for wires laid uncovered in air up to 5 m in length.
Gas supply
The following table shows the values for the gas supply:
Fuels
Flue gas connection
Gas consumption
The following table lists the gas consumption of the gas appliances:
Natural gas (H) G20
Natural gas (L) G25
Liquid gas G30/G31*
* up to 15% higher consumption for butane G30
Installation manual
6.10
6.20
Table-top applian-
ces
[kW]
1,2
1,2
[A]
2,9
2,9
[A]
16
16
2
[mm
]
5G2.5
5G2.5
[kW]
1,4
1,4
[A]
4,9
4,9
[A]
16
16
2
[mm
]
5G2.5
5G2.5
6.10
6.20
Table-top applian-
ces
Natural gas, liquid gas
Air conditioning system with safety shutdown
6.10
6.20
3
[m
/h]
1,3
2,1
3
[m
/h]
1,5
2,5
[kg/h]
0,9
1,5
103
10.10
10.20
12.20
Floor-standing
appliances
1,2
1,5
1,5
2,9
3,6
3,6
16
16
16
5G2.5
5G2.5
5G2.5
1,4
1,8
1,8
4,9
6,2
6,2
16
16
16
5G2.5
5G2.5
5G2.5
10.10
10.20
12.20
Floor-standing
appliances
10.10
10.20
12.20
2,1
3,7
4,2
2,5
4,3
4,9
1,5
2,7
3,1
20.10
20.20
2,2
2,2
5,1
5,4
16
16
5G2.5
5G2.5
2,6
2,7
9,1
9,4
16
16
5G2.5
5G2.5
20.10
20.20
20.10
20.20
4,2
7,4
4,9
8,6
3,1
5,4