Checklists and completion of installation
Water supply
Has the water drain been installed with an open drain connection?
Table-top appliances:
Is the funnel trap situated beside the combi steamer?
Table-top appliances:
Is the funnel trap situated behind the combi steamer?
Floor-standing appliances:
Has the water drain been installed with an open tank?
Floor-standing appliances:
Has the water drain been installed with a gully?
Table-top and floor-standing appliances:
Has a different drain installation been chosen?
Is the size of the customer's water drain pipe at least DN 50?
Does the water drain have a slope of at least 5 % or 3° ?
Gas supply
Has the gas system and flue system been installed correctly?
Has the gas system and flue system been approved by the registered chimney sweep?
Are there only non-flammable ceilings/materials above the appliance?
Installation
Has the protective film been removed from the appliance?
Installation manual
133
Yes
Yes
Yes
Yes