To reduce the risk of electrical shock or unsupervised usage of the equipment, always unplug the power cord from the
!
wall outlet and the machine and wait 5 minutes before cleaning, maintaining or repairing the machine. Place the power
cord in a secure location.
1. Unplug the power cord from the machine and wait 5 minutes.
2. Using a #2 Phillips screwdriver, remove the 6 indicated screws from the
Rear Step.
3. Remove the Rear Step.
4. Using the 5mm hex wrench, remove the lower mounting bolt from the
Cylinder.
5. Disconnect the Cylinder from the Treadle. Leave the top attached.
The Treadle will fall abruptly if not supported. Keep hands
away from the inside of the Treadles to avoid possible
serious injury.
The Walking Belts can abruptly move. To avoid possible
serious injury, keep hands away from the edges of the
Walking Belts.