Standby Mode; Power Save Mode - Canon imageRUNNER 5065 series Service Manual

Table of Contents

Advertisement

Chapter 9
[1] Fixing roller 1/4-speed rotation
[2] Fixing roller 1/1-speed rotation

9.2.6 Standby Mode

iR5065 / iR 5055 / iR5075 / / /
<Characteristics>
- The machine decreases the target temperature by 5 deg C at specific time intervals after a shift to standby mode (to limit power consumption).
- The target temperature and the timing at which it is changed vary depending on the environment temperature (lower than or higher than 17 deg C).
- The target temperature is decreased in steps and, thereafter, maintained to the following:
185 deg C if the environment temperature is less than 17 deg C
180 deg C if the environment temperature is 17 deg C or higher
- If the environment temperature is lower than 17 deg C,
- If the environment temperature is 17 deg C or higher,
MEMO:
The time that passes from a shift to standby mode is monitored continuously while a copy/print job is under way, and is used for temperature control for copying/
printing. (See the descriptions under "Copying/Printing Mode.")

9.2.7 Power Save Mode

iR5065 / iR 5055 / iR5075 / / /
9-6
POWER ON
(deg c)
250
200
[1]
150
100
50
0
0
5
STANDBY
(deg c)
215
210
205
200
195
190
185
180
175
0
0
180
STANDBY
(deg c)
215
210
205
200
195
190
185
180
175
0
0
60
STANDBY
[2]
10
15
20
F-9-9
360
540
720
F-9-10
120
180
240
F-9-11
25
30
(sec)
900
1080
(sec)
300
360
(sec)
0015-4592
0015-4593