- The machine decreases the target temperature by 5 deg C at specific time intervals after a shift to standby mode (to limit power consumption).
- The target temperature and the timing at which it is changed vary depending on the environment temperature (lower than or higher than 17 deg C).
- The target temperature is decreased in steps and, thereafter, maintained to the following:
185 deg C if the environment temperature is less than 17 deg C
180 deg C if the environment temperature is 17 deg C or higher
- If the environment temperature is lower than 17 deg C,
- If the environment temperature is 17 deg C or higher,
MEMO:
The time that passes from a shift to standby mode is monitored continuously while a copy/print job is under way, and is used for temperature control for copying/