Pin Assignments - SATO CL608e Operator's Manual

Cl series "e" thermal transfer printers
Hide thumbs Also See for CL608e:
Table of Contents

Advertisement

Section 6. Interface Specifications
EXT CONNECTOR
The EXT connector on the rear panel of the CL Series "e" printers is intended for use
with the external printer accessories such as label rewinders or applicators. The
14-pin Centronics type connector provides a choice of four different output signals
along with various error conditions.

Pin Assignments

PIN
DIRECTION
13
To Host
10
To Host
4
To Host
7
To Printer
5
To Printer
6
To Host
1
To Host
3
To Host
2
Reference
8
To Printer
9
To Host
11
12
To Host
14
NOTE: The signals on pins 1, 3, 4, 6, 9 and 10 each have an open collector output. These pins normally measure
+.07V maximum when a true condition exists. If a false condition occurs, the voltage will drop to 0V. To achieve a sig-
nal level of +5V, you must add a 330 ohm, 1/4W pull-up resistor between the open collector output pin and Vcc (pin
13) as illustrated . This will provide a signal level of +5V for a true condition and 0V when a false condition exists. The
maximum voltage that can be applied to these pins is +50V and the maximum current they can sink is 500 milliamps.
Page 6-12
SIGNAL DESCRIPTION
Vcc - +5V
Ribbon Near End - This pin goes high when the amount of ribbon
on the unwind shaft is approximately 46 feet (14 m). The output
will be low when the ribon is completely out.
Error - This pin goes low when the printer detects an error
condition such as head open or receiving buffer full.
Reprint - A duplicate of the last label in a print job will be reprinted
when this signal is received.
Print Start - The printer will print one label when this pin is pulled
to ground. This signal must be enabled by placing switch DSW3-5
on the Control Panel in the OFF position.
End Print - It is used to drive an applicator or other external device
requiring synchronization with the print cycle. You may choose
between four types of output signals using control panel DSW3-6
and DSW3-7 selections.See timing charts on next page.
Label Out - This pin goes low (0V) when a label out error exists.
Ribbon Out - This pin goes low (0V) when the ribbon is out.
Signal Ground
Reserved
Off Line - This pin goes low (0V) when the printer if Off Line.
Reserved
+24V +/- 10% @2A - Power for external devices.
Frame Ground
PN 9001074 Rev. B