USER PROGRAMMING FLOW CHART
& MODE
Depending on current option settings, some displays
NOTE:
cannot be viewed or set.
Entering User Mode
Press and hold the Up and Down buttons for 5 seconds at any
time other than 12:01 PM.
1. Enter User Mode
• Press and hold the Up and Down buttons for 5 seconds.
2. Set Feed Water Hardness
• Press the Shift, Up, and Down buttons to move the cursor
and change the value of the numbers.
• Press the Extra Cycle button to proceed to the next step.
Only displayed when a metered option is chosen
NOTE:
under System Type.
3. Set Regeneration Day Override
• To turn on and set the days, press the Down button.
• Press the Shift, Up, and Down buttons to move the cursor
and change the value of the numbers.
• Press the Extra Cycle button to proceed to the next step.
4. Regeneration Time
• Press the Shift, Up, and Down buttons to move the cursor
and change the value of the numbers.
• Press the Extra Cycle button
5. End of User Programming Mode
DIAGNOSTIC PROGRAMMING MODE FLOW
CHART
Depending on current option settings, some displays
NOTE:
cannot be viewed or set.
Entering Diagnostic Mode:
1. Press and release the "D" button.
2. Press the Extra Cycle button once per display until all
displays are viewed and the normal display screen appears.
3. Press and release the "D" button during this mode to exit
the Diagnostic Mode.