MASTER PROGRAMMING MODE
CONTINUED
14. Brine Line Flow Control Size
This program step allows the selection of the desired brine
line flow control size in the unit (must match physical brine
line flow control).
• Press the Up or Down buttons to adjust this value.
• Press the Extra Cycle button.
15. Auxiliary Relay Output
The next two displays are part of a series of settings used to
program the optional relay output. The first setting turns the
output on/off during regeneration only. The second turns the
output on during service only, every time a set volume of water
used has accumulated.
When auxiliary outputs are in the OFF (default)
NOTE:
setting, press the Up or Down buttons to set the first
setting. Then press the Extra Cycle button to advance
to the second setting.
a. Timed Auxiliary Relay Output Window
(Start & End Time Setting)
This option setting consists of two displays. The first display
sets the turn-on time of the output, referenced to the start
of the first regeneration cycle. The second display sets the
output turn-off time, referenced again to the start of the first
regeneration cycle. An OFF setting cancels this setting. All
settings are in minutes and output timing is synchronized with
regeneration cycle timing.
Start Time: Any time during regeneration.
End Time: At start time, and anytime during the
regeneration cycle.
b. Chemical Pump Auxiliary Relay Output Window
This option setting consists of two displays. The first display
sets the volume of water flow at which the output turns on.
The second display sets the on time (in seconds) of the output.
• Activate output after volume set is reached.
• Press the Shift button to select the digit you want to modify.
• Press the Up or Down buttons to adjust this value.
• Press the Extra Cycle button.
10 • FLECK
XT Service Manual
16. Flow Meter Size
This program step sets the size of the flow meter.
• Press the Up or Down buttons to adjust this value.
• Press the Extra Cycle button.
17. Maximum Flow Rate
This program step sets maximum flow rate of the generic
flow meter.
• Press the Shift button to select the digit you want to modify.
• Press the Up or Down buttons to adjust this value.
• Press the Extra Cycle button.
18. Pulses per Gallon/Liter
This program step sets the pulses per gallon/liter for generic
flow meters.
• Press the Shift button to select the digit you want to modify.
• Press the Up or Down buttons to adjust this value.
• Press the Extra Cycle button.
19. End of Master Programming Mode