Packed Process Data - GE RSTi-EP User Manual

Standalone 1ghz programmable controller
Hide thumbs Also See for RSTi-EP:
Table of Contents

Advertisement

EP-5442
2 Channels PWM Output, Positive Logic, 24VDC, 2 A
EP-7631
Power Module, 1 Channel 24VDC Input Flow 10A
EP-7641
Power Module, 1 Channel 24VDC Output Flow 10A
EP-1901
1 Safe Feed-Input, 24 VDC
EP-1902
2 Safe Feed-Inputs, 24 VDC, Programmable Delay
EP-1922
2 Safe Feed-Inputs, 24 VDC
EP-711F
Power Module, 16 Channels 24VDC Potential Distribution +24 VDC from Input Current Path
EP-751F
Power Module, 16 Channels 24VDC Potential Distribution +24 VDC from Output Current Path
EP-700F
Power Module, 16 Channels 24VDC Potential Distribution Functional Earth
EP-710F
Power Module, 16 Channels 24VDC Potential Distribution +0VDC from Input Current Path
EP-750F
Power Module, 16 Channels 24VDC Potential Distribution +0VDC from Output Current Path

4.4.5 Packed Process Data

Packed input process data
Input register range: 0x0000 to 0x01FF
Note: Access to all 512 registers is always possible regardless of the I/O structure. Unused registers
respond with "0".
Packed output process data
Output register range: 0x0800 to 0x09FF
Note: Access to all 512 registers is always possible regardless of the I/O structure. Unused registers
send "0" during a read access, write accesses are ignored.
Structure of packed process data
The byte granularly packed process data contains all input data (register range 0x0000 to 0x01FF)
and output data (register range 0x0800 to 0x09FF) of the RSTi-EP station.
Note: The start address(es) of each module's process data are listed in register 0x2B00 – 0x2B7F
(refer to the section 0x2B00 – 0x2B7F Module offsets of process data).
Note: Process data is mapped according to how the modules are arranged. To avoid larger gaps in
the process data, the different modules should be arranged in an optimal manner.
Product
EPXMBE001/EPXMBE101
EP-4164
EP-3164
EP-1214
EP-1214
EP-125F
GFK-2958E
Chapter 4 Detailed Descriptions of the Fieldbus Network Adapters
Power Feed Modules for Input Current Path
Power Feed Modules for Output Current Path
Safe Feed-input Modules
Potential Distribution Modules
Example of an Optimal Module Arrangement
Input
Output
Number of
input
data
data
registers
--
4 words
4 words
--
1 Byte
--
1 Byte
--
2 Byte
RSTi-EP User Manual
Number
Remarks
of output
registers
0
0
0
4
allocated 4 registers
4
0
allocated 4 registers
1
0
allocated 1/2 register low byte (1 byte)
0
0
allocated 1/2 register high byte (1 byte)
1
allocated 1 register
85