Parameter
IP address
Subnet mask
Gateway
Webserver via Ethernet
IP address USB port
Process alarm
Diagnostic alarm
Type of diagnostic
Behavior of outputs on fieldbus
errors
Module behavior on hot swap
Data format
Lock force mode
Change requires restart of the network adapter.

4.2.4 Supported Modules and Power Supplies

The following modules can be used with this release of the RSTi-EP PROFINET Network Adaptor:
Catalog Number
EP-1214
Digital Input, 4 Points, Positive Logic 24VDC, 2,3, or 4 Wire
EP-1218
Digital Input, 8 Points, Positive Logic, 24VDC 2 Wire
EP-1318
Digital Input, 8 Points, Positive Logic, 24VDC 3 Wire
EP-125F
Digital Input, 16 Points, Positive Logic, 24VDC, 1 Wire
EP-12F4
Digital Input, 4 Points, Positive Logic 24VDC, 2,3, or 4 Wire, Time stamp
EP-1804
Digital Input, 4 Points 110/230 VAC (65 – 277 VAC), 2 Wire, Isolated
EP-2214
Digital Output, 4 Points, Positive Logic 24VDC, 0.5A, 2,3, or 4 Wire
EP-2614
Digital Output, 4 Points, Positive Logic 24VDC, 2.0A, 2,3, or 4 Wire
EP-2634
Digital Output, 4 Points, Positive/Negative Logic 24VDC, 2.0A, 2,3, or 4 Wire
EP-2218
Digital Output, 8 Points, Positive Logic, 24VDC, 0.5A, 2 Wire
EP-225F
Digital Output, 16 Points, Positive Logic, 24VDC, 0.5A, 1 Wire
EP-2714
Digital Relay Output, 4 Points, Positive Logic, 24 - 220 VDC/VAC, 6A, 2 Wire
EP-2814
Solid-state Relay Output Module
GFK-2958E
Chapter 4 Detailed Descriptions of the Fieldbus Network Adapters
Overview of Editable Parameters EPXPNS001
Optional values
4 numbers between 0 and 255
4 numbers between 0 and 255
4 numbers between 0 and 255
disabled / enabled
192.168.1.202; 192.168.2.202, 192.168.3.202,
192.168.4.202, 192.168.5.202
disabled / enabled
disabled / enabled
Extended channel diagnostic (short
diagnostic)
Manufacturer-specific diagnostic (complete
diagnostic)
All outputs off / Enable substitute value / Hold
last value
Continue data exchange /
Behavior like fieldbus error
Motorola / Intel
Force mode unlocked / Force mode locked
Module Description
Digital Input Modules
Digital Output Modules
Digital Relay Output Modules
RSTi-EP User Manual
Default
disabled
192.168.1.202
disabled
disabled
Extended channel diagnostic
(short diagnostic)
All outputs off
Continue data exchange
Motorola
Force mode unlocked