Manufacturer
Castrol
Lubcon
Shell
FAG
Table 9-6
Manufacturer
Lubcon
For the Performance version, only this special lubricating grease may be used.
CAUTION
Damage caused by mixing lubrication types
Mixing different greases adversely affects the lubricating properties and must therefore be
avoided. Only the manufacturer can provide a guarantee as to whether certain greases can
be mixed.
Regreasing
Regreasing data are stamped on the lubricant plate of the machine:
● Relubrication intervals in operating hours
● Regreasing amount in grams
● Grease type
Irrespective of the actual number of operating hours, the machine must be regreased every
12 months at the latest.
CAUTION
Relubrication intervals
The relubrication intervals for roller bearings are different from the servicing intervals for the
machine. Failure to observe the relubrication intervals can result in damage to roller bearings.
Pay attention to the instructions on the lubricant plate.
Grease replacement intervals
The grease replacement intervals in these operating instructions or the relubrication intervals
indicated on the plate apply for the following conditions:
● Normal load
● Operation at speeds in accordance with the rating plate
● Low-vibration operation
SIMOTICS M-1PH8
Operating Instructions 05/2012 A5E03986435A AA
Grease type
Longtime PD2
Turmogrease L 802 EP plus
Retinax LX2
Arcanol Multi 2
Lubricating grease for the Performance version (Option L37)
Grease type
Sintono GPE702
Maintenance
9.3 Inspection and maintenance
95