Communication That Do Not Require The Sequence Program; Fms Service; Connection With Aj71Pb96F/A1Sj71Pb96F (Initiate: Responder) - Mitsubishi Electric A1SJ71PB96F User Manual

Melsec a series, profibus modules, a(1s)j71pb96f
Table of Contents

Advertisement

7. COMMUNICATION THAT DO NOT REQUIRE
THE SEQUENCE PROGRAM
7. COMMUNICATION THAT DO NOT
REQUIRE THE SEQUENCE
PROGRAM
This chapter explains the communication service parameters that can be specified in the client when
the AJ71PB96F/A1SJ71PB96F is operating as a server.
7.1

FMS Service

7.1.1
When communicating with the AJ71PB96F/A1SJ71PB96F, the client issues an Initiate service to
establish a connection.
[Parameters required by the client]
• Version 0D (Calling)
• Profile Number (Calling)
• Access Protection Supported (Calling)
• Password (Calling)

Connection with AJ71PB96F/A1SJ71PB96F (Initiate: Responder)

OD version number
Version OD value
Client OD version
Specify the profile number.
Profile number supported by the client
Specify whether or not the access protection is supported.
Access Protection value
False = 0
False = FF (hex)
Password allocated to each connection
Password value
00 (hex)
Profile Number value
Meaning
Not supported
Supported
7-1
MELSEC-A