7. COMMUNICATION THAT DO NOT REQUIRE
THE SEQUENCE PROGRAM
7.1.17
The UpSegument is transmitted from the client after the InitiateUploadSequence terminates normally.
[Parameters required by the client]
• Access Specification
[Server (AJ71PB96F/A1SJ71PB96F) answer parameters]
• Load Data
Note
The AJ71PB96F/A1SJ71PB96F transmits the data in 128 byte units. For this reason, make the
CRL Max send PDU (low) value 200 or more.
• More Follows
Uploading program, parameter, comment, and device buffer memories
(UploadSegument: Server)
Specify the Index or Name of the domain specified by InitiateUploadSequence.
Access Specification
Index
Variable Name
The read data is set.
This notifies whether or not data remains to be uploaded.
More Follows value
False = 0
True = FF (hex)
Setting value
Domain Index
Domain Name
Meaning
No more data remains to be uploaded.
More data remains to be uploaded.