Pre Installation Configuration; Encryption; Communicator Installation Configuration - DSC GS2060-SM Installation Manual

Alarm communicator, gprs cellular communicator, ethernet/internet communicator, ethernet/internet and gprs dual-path communicator
Table of Contents

Advertisement

Communicator
GS2060-SM
TL260-SM
TL260GS-SM
NOTE: Enter [*][8][Installer Code][900] at keypad to view the Panel Version number.
Products or components of products, which perform communications functions only shall comply with the
requirements applicable to communications equipment as specified in UL60950 or CAN CSA C22.2. No.
60950-1, Information Technology Equipment - Safety - Part 1: General Requirements. Where network inter-
faces are internal to the control unit or receiver, compliance to CAN CSA C22.2. No. 60950-1 is adequate. Such
components include, but are not limited to: hubs; routers; NIDs; Third party communications service providers;
DSL modems; and Cable modems.
Software Compatibility
The Communicator is compatible with the following ADT Pulse software:
iControl Interactive.
System Administrator.
ADT Pulse
NOTE: This application has not been investigated by UL/ULC and is not used on UL/ULC certified
installations.
The Communicator provides ADT Pulse Level 1, 2, and 3 monitoring and control via an RS-422 interface to an
external iHub. The default Keybus link speed is 115.2 KB and this option is programmable by the installer. All
life-safety events are encrypted and transmitted by the GPRS path to the central monitoring station (Level 1).
All life-style events are transmitted by the RS-422 link, using ITv2.0 protocol to the iHub, and then to remote the
iControl Servers (Level 2 and Level 3).
NOTE: iControl's iHub is an interface device which connects to security panels, IP cameras, sensors,
Z-wave based home automation devices, etc. to deliver a host of advanced functionality.
NOTE: Life-style events are "non alarm" events. Life-safety events are "alarm" events.
There are three ADT Pulse levels, defined as follows:
•.L1: GPRS Remote Control of Arm/Disarm and notification for doors and windows. All life-safety and life-style
events are transmitted on the GPRS channel only.
•L2: Broadband with Z-Wave and L1. Life-safety events use GPRS channel. Life-style events use RS-422.
•L3: Broadband with L1, L2, and video. Life-safety events use GPRS channel. Life-style events use RS-422.
The following features are available with the RS-422 ADT Pulse Interface:
Communicator faults can be transmitted.
Panel communication errors are reported to the ADT iHub.
Real time reporting of Zone status information to the ADT iControl Server.
Remote update of the Communicator (flash upgrade).
SMS incoming "wake up" for the GPRS channel.
WEB login to request an incoming session with the Communicator.
Zone Label Programming.
NOTE: Communicator buffers 1,000 date/time stamped Life-Style events to iHub as First In First Out (FIFO).

Encryption

The Communicator uses 128 Bit AES Encryption. Encryption can only be enabled from the monitoring station
receiver. Each receiver (Ethernet 1 and 2, GPRS 1 and 2) can independently have encryption enabled or dis-
abled. When encryption is enabled, the central station will configure the device to encrypt communications the
next time the Communicator module performs a communication to that receiver.
NOTE: Packets will start being encrypted only after the next event is sent to that receiver, or if the unit
is restarted.
Before leaving the installation site, the Communicator TL260-SM/TL260GS-SM Ethernet line shall be
connected via an APPROVED (acceptable to the local authorities) Network Interface Device (NID) (e.g.,
for UL Installations, U60950 listed NID). All wiring shall be performed according to the local electrical
codes.

COMMUNICATOR INSTALLATION CONFIGURATION

This GPRS/Ethernet Communicator shall be installed by Service Persons only. (Service Person is defined as a per-
son having the appropriate technical training and experience necessary to be aware of hazards to which that person
may be exposed in performing a task and can also take measures to minimize the risks to that person or other per-
sons). The Communicator shall be installed and used within an environment that provides the pollution degree max
2, overvoltages category II, in non-hazardous, indoor locations only. This manual shall be used with the Installation
Manual of the panel which is connected to the GPRS/Ethernet Communicator. All instructions specified within the
panel manual must be observed.
All the local rules imposed by local electrical codes shall be observed and respected during installation.
Receiver/
Panel
• Sur-Gard System I Receiver, version 1.30+
• Sur-Gard System II Receiver, version 2.10+
Receiver
• Sur-Gard SG-DRL3-IP, version 2.30+ (for Sur-Gard System III Receiver)
• Sur-Gard SG-DRL4-IP version 1.20+ (for Sur-Gard System IV Receiver)
• Power Series PC1616, version 4.5+
Panel
• Power Series PC1832, version 4.5+
• Power Series PC1864, version 4.5+

PRE INSTALLATION CONFIGURATION

Table 2: Compatible Receivers, and Panels
Description
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tl260-smTl260gs-sm