Pre Installation Configuration; Communicator Installation Configuration - DSC PowerSeries Neo 3G2080E Installation Manual

Cellular alarm communicator, internet and hspa dual-path alarm communicator, internet alarm communicator
Hide thumbs Also See for PowerSeries Neo 3G2080E:
Table of Contents

Advertisement

Model
Current Consumption
Standby Current
Alarm (Transmitting)
Current
Operating Frequency
Typical Antenna Gain
Environmental Specifications
Operating Temperature
Humidity
Mechanical Specifications
Board Dimensions (mm)
Weight (grams) with
bracket
Communicator Receiver/Panel
3G2080(R)E
Receiver
TL2803G(R)E Panel
NOTE: Enter [*][8][Installer Code][900] at keypad to view the panel version number.
Encryption
The communicator uses 128 Bit AES encryption. Encryption can only be enabled from the monitoring station receiver. Each
receiver (Ethernet 1 and 2, cellular 1 and 2) can independently have encryption enabled or disabled. When encryption is
enabled, the central station will configure the device to encrypt communications the next time the communicator module per-
forms a communication to that receiver.
NOTE: Packets will start being encrypted only after the next event is sent to that receiver, or if the unit is restarted.
Before leaving the installation site, the communicator TL2803G(R)E Ethernet line shall be connected via an APPROVED
(acceptable to the local authorities) Network Interface Device (NID). All wiring shall be performed according to the local
electrical codes.
This HSPA(3G)/dual- path alarm communicator shall be installed by service persons only (service person is defined as a per-
son having the appropriate technical training and experience necessary to be aware of hazards to which that person may be
exposed to in performing a task and can also take measures to minimize the risks to that person or other persons). The Com-
municator shall be installed and used within an environment that provides the pollution degree max 2, overvoltages category II,
in non-hazardous, indoor locations only. This manual shall be used with the installation manual of the panel which is con-
nected to the communicator. All instructions specified within the panel manual must be observed.
All the local rules imposed by local electrical codes shall be observed and respected during installation.
3G2080(R)E
Cellular only
Power is supplied from the panel's PC-Link header or a PCL-422 module in remote cabinet
installations. In remote cabinet installations, the PCL-422 module located with the communicator is
powered by either an HSM2204 or an HSM2300. Refer to the PCL-422 installation instructions for
90mA @ 13.66V
100 × 150 × 15
310
Table 2: Compatible Receivers and Panels
Sur-Gard System I-IP Receiver, version 1.13+
l
Sur-Gard System II Receiver, version 2.10+
l
Sur-Gard SG-DRL3-IP, version 2.30+ (for Sur-Gard System III Receiver)
l
Sur-Gard SG-DRL4-IP version 1.20+ (for Sur-Gard System IV Receiver)
l
Sur-Gard SG-DRL5-IP version 1.00+ (for Sur-Gard System 5 Receiver)
l
HS2016
l
HS2016-4
l
HS2032
l
HS2064
l
HS2128
l

Pre Installation Configuration

Communicator Installation Configuration

TL280(R)E
Internet only
details.
400mA @ 12V
900MHz, 1800MHz, 2100MHz
2dBi
-10°C to 55°C
5% ~ 93% relative humidity, non-condensing
Description
5
TL2803G(R)E
Internet and Cellular
120mA @ 13.66V
100 × 150 × 15
320