UL/ULC Installation Requirements

NOTE: For equipment used at the protected premises and intended to facilitate IP communications (hubs,
routers, NIDs, Digital Subscriber Line (DSL), Cable modems), 24 hour back-up power is required. Where
such cannot be facilitated, a secondary (back-up) communication channel is required.

Domain Name Service (DNS) programming is not permitted in UL/ULC listed systems.
Notes for using Private, Corporate, and High Speed Data Networks:
Network access and domain access policies shall be set to restrict unauthorized network access, and spoofing
or Denial of Service (DoS) attacks. Select an Internet Service Provider (ISP) that has redundant servers/sys-
tems, back-up power, routers with firewalls enabled, and methods to identify and protect against DoS attacks
(e.g., via spoofing).
Notes for using Public Switched and Cellular Data Networks:
Communication channels shall be facilitated such that the Communicator will restrict unauthorized access,
which could otherwise compromise security. The Communicator shall be located in a secured area.
For ULC Residential Fire and Burglary applications the TL260GS-SM can be used as primary communica-
tion channel via either GSM or Ethernet or as a back-up in conjunction with the Digital Alarm Communicator
Transmitter (DACT). Test transmission every 24 hours shall be enabled on each channel.
For ULC Commercial Fire and Burglary applications the GS2060-SM and TL260GS-SM can be used as a
passive communication module with the following Security Levels:
P1 (each channel GSM or Ethernet is independent),
P2 (GSM and Ethernet in back-up configuration, Panel Section [851][005] Toggle Option [5] OFF),
P3 (GSM and Ethernet in redundant configuration, Panel Section [851][005] Toggle Option [5] ON).
The Communicator can also be used as an Active communication system with the Security Levels A1-A4
(each channel GPRS or Ethernet independent or together in a back-up/redundant configuration). For Active
Line Security systems AES128 bit encryption shall be enabled (at the monitoring station receiver) and the
supervision heartbeat rate shall be set as 90 seconds (Panel Section [851][004] = 005A/90). The supervi-
sion window at the Signal Receiver Center (SRC)'s receiver shall be programmed as maximum of
180 (00B4/180) seconds.
For UL Residential Fire and Burglary applications the GS2060-SM andTL260GS-SM can be used as the
primary communication channel via either GSM or Ethernet, or as a back-up in conjunction with the DACT
(30 day test transmission is required on each channel).
For UL Commercial Burglary applications the TL260GS-SM can be used as Dual Signalling Line communi-
cation system (GPRS and Ethernet channels used in redundant configuration), Standard Line Security and
as Encrypted Line Security.
The supervision heartbeat shall be enabled (Panel Section [851][005] Toggle Option [1] (Ethernet) and/or
Toggle Option [2] (GSM) shall be ON), Toggle Option [3] (Supervision Type) shall be ON and the supervision
heartbeat rate shall be selected as 135 (0087/135) seconds. Option [004] = 0087. The supervision window
at the supervising station shall be maximum 200 (00C8/200) seconds. For Encrypted Line Security systems
the encryption AES128 bit shall be enabled at the monitoring station receiver.
For UL Commercial Burglary installations, the GS2060-SM is listed as a primary (sole) communication
means (heartbeat must be enabled) or for supplementary (back-up) use in conjunction with a Plain Old Tele-
phone Service (POTS) line dialer. When the heartbeat transmission over the Ethernet or GPRS network is
enabled, using the TL260GS-SM with a compatible control unit listed for standard/encrypted line security, it
can provide line security for the alarm system over the primary line.
The TL260GS-SM is also suitable to be used with a compatible control unit listed for dual line security trans-
mission when used in conjunction with a DACT or a Public Switched Data Network (PSDN) transmitter,
where the PSDN provides the line security and is the primary line. In this mode, alarm signals are required
to be sent simultaneously over both communication methods.

RatingsCompatibility

Model
POWER SUPPLY RATINGS
Input Voltage
CURRENT CONSUMPTION
Standby Current
Alarm (Transmitting) Current
Operating Frequency
Typical Antenna Gain
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Humidity
MECHANICAL SPECIFICATIONS
Board Dimensions (mm)
Weight (grams) with bracket
GS2060-SM
GPRS only
The panel Bell output shall be derated:
700mA - (Communicator mA) = (derated Bell output).
90mA @ 13.66V
Quad band 850MHz, 900MHz, 1800MHz, 1900MHz
5% ~ 93% relative humidity, non-condensing
100 × 150 × 15
310
4
Table 1: Communicator Ratings
TL260-SM
Ethernet only
Nominal 12 VDC:
100mA @ 13.65V
400mA @ 12V
2dBi
32°F - 120°F (0°C - 49°C)
100 × 150 × 18
290
TL260GS-SM
Ethernet & GPRS
120mA @ 13.66V
100 × 150 × 15
320