MBT-5003 L-Band Up/Down Converter System
Front Panel Operation
5.3.2

SELECT: Monitor

Note: Low Noise Amplifier (LNA) operation is not supported by the MBT-5003. The LPT
selection on this submenu is therefore nonfunctional.
Monitor: Faults Mask
Event-Log LPT
◄ ►
Use the
arrow keys to select from the submenu choices shown, then press ENT. The following
table identifies each submenu available from the SELECT: Monitor menu branch – typical for
Converter Unit A or Unit B – its content section in this chapter, and functional description of each
submenu:
Submenu
Faults
Mask
Event-Log
5.3.2.1

MONITOR: Faults

Live Faults: Unit ConvA
ConvB
Select Unit, ConvA, or ConvB using the
If Unit is selected, the highest level fault for the base unit will appear. If no Unit faults exist,
the message "
Unit Fault:
No Errors
Press ENT to return to the previous menu.
If ConvA or ConvB is selected, the highest fault for the converter will appear. If no converter
faults exist, the message "
ConvA Fault:
No Errors
Press ENT to return to the previous menu.
5.3.2.2

MONITOR: Mask

Note: The Power selection on this submenu is operable only when the MBT-5003-XUR is
optionally configured with the Power Monitor option. Low Noise Amplifier (LNA) operation is
not supported by the MBT-5003 – the LNA selection is therefore nonfunctional.
Alarm Mask: Power ExtRef
ConvA ConvB LNA
Sect
Functional Description
5.3.2.1
Displays the active faults for the base unit and the converters.
5.3.2.2
Permits the user to configure Alarm Mask (MSK) conditions.
5.3.2.3
Display stored events. Also permits the user to clear the events.
(◄ ► E)
No Errors
" is displayed:
No Errors
(◄ ► E)
◄ ►
arrow keys, then press ENT.
" is displayed:
5–11
Revision 1
MN-MBT5003