Garmin G1000 NXi Supplemental Maintenance Manual page 87

Hide thumbs Also See for G1000 NXi:
Table of Contents

Advertisement

Key Alerts
Failure Message
MFD "key" KEYSTK – key is
stuck.
PFD "key" KEYSTK – key is stuck.
Miscellaneous Alerts
Failure Message
XTALK ERROR – A flight display
cross talk error has occurred.
DATA LOST – Pilot stored data
lost. Recheck settings.
G1000 Supplemental Maintenance Manual
Textron Nav III Series
190-02128-04
Cause
The SYSTEM has determined a
key is stuck on MFD.
The system has determined a key
is stuck on the PFD.
Cause
A communication error has
occurred between the MFD and
PFD.
Pilot stored data has been lost.
Solution
Go to the GDU TEST page in
configuration mode and verify key
is stuck (if key is stuck the
corresponding indicator will be
green).
Exercise suspected stuck key and
reset GDU TEST page to see if
indicator remains green without
pressing the key.
If problem persists replace the
display.
Solution
Ensure a database error has not
occurred (identified in the ALERTS
window on the PFD).
If a database error has
occurred, correct error before
proceeding.
Check display Ethernet
interconnect wiring.
Replace PFD with a known good
unit, to verify location of problem:
If problem persists, reinstall
original PFD and replace MFD.
If the CLR key was held during a
power cycle, disregard message.
Cycle power to PFD:
Ensure CLR key is not stuck
on the GDU TEST page.
If problem persists, replace
PFD.
Page 5-19
Revision 3

Advertisement