3.8

Feature Enablement

This section describes how to unlock or enable optional features. The installer will only load the
sections for the features they require. For installing all feature enablement cards, the PFD and
the MFD must be in configuration mode.
The G1000 has various features that require the use of unlock/enable cards to activate the
feature. Throughout this document these cards are generically referred to as 'enablement
cards'. In some cases, the actual label on the physical card may say 'unlock'.
If uncertain what SD Card to use, the technician must verify the card part number on the
General Arrangement drawing prior to use to assure the correct feature is unlocked.
ChartView Feature Enablement
Follow this procedure to activate Jeppesen ChartView. Enabling this feature, allows the pilot to
switch between Garmin FliteCharts and Jeppesen ChartView products.
The required ChartView databases are subscription-based and need to be
procured by the installing agency from the Garmin or Jeppesen website. The
ChartView database is not present in a new display.
Insert the ChartView Enablement card in the top slot of the PFD and power on the PFD
in configuration mode.
If a message appears on the PFD stating an "arfrm_imgs.zip" file is not present, follow
the on screen instructions to continue. This file will be loaded in Section 3.11
On the PFD, select the "System Upload" page using the small FMS knob.
Push in the FMS knob to activate the cursor in the Group field. Rotate the small FMS
knob to highlight "Configuration Files" and press the ENT key to select it.
In the ITEM window, rotate the small FMS knob to highlight "Enable ChartView" and
press the ENT key to select it.
Press the Load softkey.
Monitor load progress. Verify software load completes without errors as indicated by the
following:
Green "PASS" in the Configuration column for each item loaded.
"Upload Complete.............COMPLETE" in the summary box.
Press the ENT key to acknowledge the prompt that appears in the pop-up box.
Open the PFD circuit breakers and remove the ChartView enablement card.
G1000 Supplemental Maintenance Manual
Textron Nav III Series
190-02128-04
NOTES
Page 3-31