Function of Indoor Unit (RA Models)
1.9
NIGHT SET Mode
Outline
When the OFF timer is set, the NIGHT SET Mode is automatically activated. The NIGHT SET
Mode keeps the airflow rate setting.
Detail
The NIGHT SET Mode continues operation at the target temperature for the first one hour, then
automatically raises the target temperature slightly in the case of cooling, or lowers it slightly in
the case of heating. This prevents excessive cooling in summer and excessive heating in winter
to ensure comfortable sleeping conditions, and also conserves electricity.
Cooling
Target temperature
Heating
94
Wall Mounted Type
Floor Standing Type
1 hour
TIMER operation
NIGHT SET Circuit ON
Floor / Ceiling Suspended Dual Type
Duct Connected Type
Target temperature
TIMER operation
NIGHT SET Mode ON
(A) : When the outdoor temperature is normal and the room
temperature is at the set temperature.
(B) : When the outdoor temperature is high (27˚C or higher).
Target temperature
TIMER operation
NIGHT SET Mode ON
0.5˚C
+0.5˚C
temperature shift
(A)
0.5˚C
1 hour
30 minutes
+0.5˚C
(A) +0.5˚C temperature shift
temperature shift
(B)
1 hour later
SiBE121021_C
Operation stops
at the set hours
0.5˚C
(B)
Operation stops
at the set hours
Target temperature remains the same
2˚C
(R10871)
Function and Control
(R10870)
(R14060)