5.3.3 NIGHT QUIET Mode
If NIGHT QUIET mode is to be used, initial settings must be made when the unit is installed.
Explain the function of NIGHT QUIET mode, as described below, to the customer, and confirm
whether or not the customer wants to use NIGHT QUIET mode.
NIGHT QUIET mode function reduces operating noise of the outdoor unit at nighttime. This
function is useful if the customer is worried about the effects of the operating noise on the
neighbors. However, if NIGHT QUIET mode is running, cooling capacity is reduced.
1. Remove the SW5 jumper switch on the service monitor PCB of the outdoor unit.
2. Install the removed jumper switch as described below. This jumper switch is needed later to
5.3.4 ECONO-mode-proof Setting
Outline
When installing in hotels, you can make ECONO mode ineffective on the outdoor unit.
Operation
The ECONO mode can be switched over between "effective" and "ineffective" by pressing the
forced operation ON/OFF switch (SW1) on the outdoor unit and wiring error check switch (SW3)
on the outdoor unit at the same time and holding them for 5 seconds while the compressor is
stopped. The LEDs are lit in turn for 15 seconds to show the ECONO mode status.
The factory setting is "effective".
Trial Operation and Field Settings
Procedure
Once the settings are complete, reset the power.
disable this setting.
LED flashing order
3 or 4 room model
5 room model
Service monitor PCB
NIGHT QUIET mode
setting switch (SW5)
Jumper switch
After removing
effective → ineffective
4 → 3 → 2 → 1
5 → 4 → 3 → 2 → 1
Field Settings
(R10814)
(R10813)
ineffective → effective
1 → 2 → 3 → 4
1 → 2 → 3 → 4 → 5