Placing the remote controller in the
remote controller holder
Install the remote controller holder to a wall
or a pillar with the attached screw. (Make
sure it transmits)
Placing the remote
controller
Slide from above
Remote
controller
holder
How to put the dry batteries
(1) Remove the back cover
of the remote controller
to the direction pointed
by the arrow mark.
(2) Put the batteries
Use two dry cell
batteries (AAA.LR03
(alkaline)). Put dry
batteries correctly to fit
their (+) and (–).
(3) Close the cover
When to change batteries
Under normal use, batteries last about a
year. However, change them whenever the
indoor unit doesn't respond or responds
slowly to commands, or if the display
becomes dark.
English
Operation Manual
[CAUTIONS]
Removing the
IN THE CASE OF CENTRALIZED
remote controller
CONTROL SYSTEM
If the indoor unit is under centralized control,
Pull it upward
it is necessary to switch the remote
controller's setting.
In this case, contact your DAIKIN dealer.
SKYAIR System
If the temperature or the humidity is beyond the
following conditions, safety devices may work
and the air conditioner may not operate, or
sometimes, water may drop from the indoor unit.
COOLING
HEATING
DB: Dry bulb temperature
WB: Wet bulb temperature
SA Indoor Unit - FFQ, FCQ, FDBQ, FBQ, FHQ Series
• Replace all batteries at the same time, do
not use new and old batteries intermixed.
• In case the remote controller is not used
for a long time take out all batteries in
order to prevent liquid leak of the battery.

4. OPERATION RANGE

INDOOR
OUTDOOR UNIT
TEMPERATURE
RS50 · 60
D
21 to 32
RKS25 · 35 ·
B
50 · 60
W
RXS25 · 35 ·
14 to 23
B
50 · 60
D
3MKS50
21 to 32
B
4MKS58 · 75 · 90
3MXS52
W
14 to 23
4MXS68 · 80
B
OUTDOOR UNIT INDOOR TEMPERATURE
RXS25 · 35 ·
D
10 to 30
50 · 60
B
3MXS52
D
10 to 30
4MXS68 · 80
B
[°C]
OUTDOOR
TEMPERATURE
HUMIDITY
80% or
D
– 10 to 46
below
B
80% or
D
– 10 to 46
below
B
[°C]
OUTDOOR
TEMPERATURE
D
– 14 to 24
B
W
– 15 to 18
B
D
– 14 to 21
B
W
– 15 to 15.5
B
6
275