Outline
When the OFF TIMER is set, NIGHT SET mode is automatically activated. NIGHT SET mode
keeps the airflow rate setting.
Details
NIGHT SET mode continues operation at the target temperature for the first one hour, then
automatically raises the target temperature slightly in the case of cooling, or lowers the target
temperature slightly in the case of heating. This prevents excessive cooling in summer and
excessive heating in winter to ensure comfortable sleeping conditions, and also conserves
electricity.
Cooling
Heating
Part 4 Functions and Control
Zone A
Zone A
Zone B
Zone B
1.0°C (1.8°F)
Zone C
Zone C
Zone A
Zone A
Zone B
Zone B
1.0°C (1.8°F)
Zone C
Zone C
Target temperature
TIMER operation
NIGHT SET Mode ON
Target temperature
TIMER operation
NIGHT SET Mode ON
Functions for Wall Mounted / Floor Standing Type
Room thermistor temperature – target temperature
OFF
OFF
1.5°C (2.7°F)
0.5°C (0.9°F)
0°C (0°F)
ON
ON
Room thermistor temperature – target temperature
OFF
OFF
1.5°C (2.7°F)
0°C (0°F)
ON
ON
0.5°C (0.9°F)
1 hour
+0.5°C (+0.9°F)
temperature shift
2°C (3.6°F)
1 hour
–2°C (–3.6°F)
temperature shift
(R24032)
(R24034)
Operation stops
at the set hour
(R23917)
(R23918)