FITTING TOP SPACER AND WALL CLIP
Once Commissioning is complete the last thing
to do is fix the top spacer.
1. Fit the spacer bracket to the top spacer.
2. Secure Heater to wall.
Replace top spacer, clipping the spacer into the
wall brackets at the same time as attaching it to
the heater. Secure top spacer with the screws
provided.
The heater is now secured to the wall.
Replace the air filter.
Spacer
Spacer bracket
Wall bracket
– 41 –
INSTRUCT CUSTOMER ON USE OF HEATER
When you are satisfied that the appliance is
operating correctly explain operation of heater to
the customer.
Fault-Finding Procedure
If you are unable to get the heater to operate
correctly contact Rinnai UK directly.
Some items are not covered by the manufacturer's
warranty.
Examples of these are: annual
maintenance, carbon build-up on flame rods/igniter,
dust, improper conversions, etc.