Rinnai RHFE-951ETR Installation Manual
Rinnai RHFE-951ETR Installation Manual

Rinnai RHFE-951ETR Installation Manual

Power flued flamefire space heater co-axial flue system
Hide thumbs Also See for RHFE-951ETR:

Advertisement

Quick Links

These components shall be installed in accordance with:
• Manufacturer's Installation Instructions
• Current AS/NZS 3000, AS/NZS 3500 & AS / NZS 5601
• Local Regulations and Municipal Building Codes
THESE COMPONENTS MUST BE INSTALLED, SERVICED AND REMOVED BY AN AUTHORISED PERSON!
ONLY THE FLUE SYSTEM COMPONENTS SPECIFIED IN THIS MANUAL MUST BE USED. COMPONENTS AND SYSTEMS
NOT SPECIFIED IN THIS MANUAL, WHETHER MANUFACTURED BY RINNAI OR OTHERWISE, ARE NOT COMPATIBLE
AND MUST NOT BE USED!
INSTALLATION MANUAL
Power Flued Flamefire Space Heater
Co-axial Flue System
USE ONLY RINNAI GENUINE PARTS
To Suit Power Flued Flamefire Models:
RHFE-750ETR - ASPIRATION
RHFE-752ETR
RHFE-950ETR
RHFE-951ETR - 950X
RHFE-1250ETR
All Rinnai gas products
are A.G.A. certified.

Advertisement

Table of Contents
loading

Summary of Contents for Rinnai RHFE-951ETR

  • Page 1 All Rinnai gas products ONLY THE FLUE SYSTEM COMPONENTS SPECIFIED IN THIS MANUAL MUST BE USED. COMPONENTS AND SYSTEMS are A.G.A. certified. NOT SPECIFIED IN THIS MANUAL, WHETHER MANUFACTURED BY RINNAI OR OTHERWISE, ARE NOT COMPATIBLE AND MUST NOT BE USED!
  • Page 2: Table Of Contents

    MODELS: RHFE-950, RHFE-951ETR & RHFE-1250ETR........
  • Page 3: Conventions Used In This Manual

    DO NOT instructions will void the warranty of an appliance and may cause injury or death. NOTE / IMPORTANT Important notes or general hints and guides provided to ease the installation. CAUTION Caution notes and or warnings that MUST BE observed for safe and correct installations. Rinnai POWER FLUED FLAMEFIRE FIM...
  • Page 4: Regulations, Clearances & General Information

    (ESROOFCOWL) are shown in exception of sub-floor ventilation: • Fig.1. • Other appliances • If in doubt contact Rinnai (phone number • Appliances over 50 MJ/h input and up to 150 MJ/h input 1000 1000 on the back page).
  • Page 5: Flue Transition Connections

    Use ONLY the supplied silicone based “O Ring” seal lubricant. DO NOT use petroleum based lubricants such as petroleum jelly. The use of petroleum jelly, CAUTION ® vaseline or similar petroleum based lubricants will cause deterioration of the “O” ring seals. Rinnai POWER FLUED FLAMEFIRE FIM...
  • Page 6: Installation Configurations

    INSTALLATION CONFIGURATIONS The following configurations are currently available. For alternative configurations contact Rinnai. DIRECT/EXTENDED Components Option A (Direct) Option B (Direct Extended) Direct Flue Kit Rinnai Flamefires ASPDFK Direct Flue Kit ASPDFK # Co-Ax Pipe 900mm (Optional) ESPIPE900 EXTERNAL WALL...
  • Page 7 8.5 metres x zero bends is permissible provided no bend is used in the flue transition connection. Note: The aluminium flue transition connection may contain one bend and this is counted as 1 (one) x 90° bend. IMPORTANT Rinnai POWER FLUED FLAMEFIRE FIM...
  • Page 8: Wall Penetrations

    55 mm from base of enclosure 378 mm LEFT of centreline 580 mm from base of enclosure plus or minus 25mm RHFE-950ETR / RHFE-951ETR Flue pipe penetration Mark the location of the gas supply (consumer piping) and flue pipe penetrations from the centreline...
  • Page 9: Flue Components

    FLUE COMPONENTS ASPDFK ASPKIT03 GLFFKITIW (Direct Flue Kit for Rinnai Flamefires) (Flue Adaption Kit (Extended Flue Adaption for Rinnai Flamefires) Kit for Rinnai Flamefires) Internal Wall Plate Condensation Trap Co-ax Verticle Terminal External Wall Plate Flue Terminal Flue Transition Silicon Grease...
  • Page 10: Flue Component Assembly

    6. Refere to the chapter “Heater Installation” in the “Rinnai Operation / Installation Manual” supplied with the heater and complete the installation and commissioning of the heater in accordance with these.
  • Page 11: Creating A "Direct Extended" Flue Installation

    6. Refere to the chapter “Heater Installation” in the “Rinnai Operation / Installation Manual” supplied with the heater and complete the installation and commissioning of the heater in accordance with these.
  • Page 12: Creating An "External Wall" Flue Installation

    Finalise Installation & Commissioning of Heater. a - f Follow steps 1 through 5 from the chapter “Heater Installation” in the “Rinnai Operation / Installation Manual” supplied with the heater. The creation of the horizontal section of flue installation is the same as creating a DIRECT or DIRECT EXTENDED flue installations with the following exceptions: The direction of horizontal fall of the flue pipe is reversed.
  • Page 13 10. Refere to the chapter “Heater Installation” in the “Rinnai Operation / Installation Manual” supplied with the heater and complete the installation and commissioning of the heater in accordance with these.
  • Page 14: Creating An "Internal Wall" Flue Installation

    6. Connect condensate drain tube to heater in accordance with the instructions on page 23. 7. Refere to the chapter “Heater Installation” in the “Rinnai Operation / Installation Manual” supplied with the heater and complete the installation and commissioning of the heater in accordance with these.
  • Page 15: Creating A "Sideways" Flue Installation

    Direct Extended Flue Installations (As Required). Finalise Installation & Commissioning Of Heater. Follow steps 1 through 5 from the chapter “Heater Installation” in the “Rinnai Operation / Installation Manual” supplied with the heater. The Sideways flue installation can run along the left or right hand side of the internal wall behind the heater. When considering the location of the heater due care must be taken to ensure that the flue path is free of obstructions such as studs, noggins, joists, braces, and electricals etc.
  • Page 16 10. Refere to the chapter “Heater Installation” in the “Rinnai Operation / Installation Manual” supplied with the heater and complete the installation and commissioning of the heater in accordance with these.
  • Page 17: Creating An "Under Floor" Flue Installation

    (1) ESBEND (1 x 90°)! Follow steps 1 through 5 from the chapter “Heater Installation” in the “Rinnai Operation / Installation Manual” supplied with the heater. The Down and Out flue option allows for a Flue Adaption Kit (ASPKIT03) to face downwards and the flue to be run vertically though a hole in the floor, and then horizontally to a suitable location outside.
  • Page 18 9. Refere to the chapter “Heater Installation” in the “Rinnai Operation / Installation Manual” supplied with the heater and complete the installation and commissioning of the heater in accordance with these.
  • Page 19: Cutting ~ Aspdfk, Aspkit03, Espipe900 & Esroofcowl Flue Pipes

    Silicone containing acetic acid, (characteristically having a vinegar odour), as the curing agent or other acids may cause corrosion of aluminium components and MUST NOT be used. Rinnai POWER FLUED FLAMEFIRE FIM...
  • Page 20: Assembling Wall Terminal ~ Aspdfk & Espipe900

    For the on wall terminal it is CRITICAL that the inner pipe components are secured with rivets or screws and that the joints of PVC outer pipes are sealed with an appropriate PVC solvent. CAUTION Rinnai POWER FLUED FLAMEFIRE FIM...
  • Page 21: Component Assembly & Connection ~ Esbend

    COMPONENT ASSEMBLY AND CONNECTION ~ ESROOFCOWL When connecting an ESROOFCOWL to other flue components use the same methods as described for connecting ESPIPE900 and observe the clearance requirements detailed in the section “REGULATIONS, CLEARANCES & GENERAL INFORMATION” on page 4. Rinnai POWER FLUED FLAMEFIRE FIM...
  • Page 22: Connecting Heater Exhaust & Air Supply

    The rubber cap (when supplied) is designed to fit both the left and right hand combustion air inlet and MUST cover the air inlet not in use. Rinnai POWER FLUED FLAMEFIRE FIM...
  • Page 23: Connecting Condensate Drain Kit To Heater

    “short end first” making sure that the tray is centered under the end of the condensate tube that was installed in step 2. MODELS: RHFE-950, RHFE-951ETR & RHFE-1250ETR 1. Insert the barbed end of the condensate tube into the...
  • Page 24: Contact Information

    Braeside, Victoria 3195 For further information visit: www.rinnai.com.au Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance. If your appliance requires service, please call our National Help Line. Rinnai recommends that this appliance be serviced every 2 years.

This manual is also suitable for:

Rhfe-752etrRhfe-950etrRhfe-750etrRhfe-1250etr

Table of Contents