Lennox iComfort M30 Installation And Setup Manual page 17

Smart thermostat
Hide thumbs Also See for iComfort M30:
Table of Contents

Advertisement

MENU
STAGE DIFFERENTIAL
STAGE DELAY
H/C STAGES LOCKED IN
STAGE 2 HP LOCK TEMP
COMPRESSOR PROTECT
DISPLAY PERFORMANCE REPORT
H/D
TERMINAL SETTINGS
ACC
O/B
SYSTEM TEST MODE
Table 5. Advanced Settings
SETTING (default is bold)
Stage 1 - 1.0°F
Stage 2 - 1.0°F
Stage 3 - 0.5°F
Stage 4 - 0.5°F
On or Off
Stage 2 through 4 - 20 min.
Enable or Disable
Off, 40°F, 45°F, 50°F, 55°F
On or Off
On or Off
Off
Humidify
Dehumidify
Off
Humidify
Dehumidify
Ventilation (future use)
O (energized during cooling)
B (energized during heating)
Confirm Button
17
Notes:
Adjustable (0.5 to 8.0°F)
Adjustable (0.5 to 8.0°F)
Adjustable (0.5 to 8.0°F)
Adjustable (0.5 to 8.0°F)
Adjustable (5 to 120 minutes)
Turns heating stages off separately
Heat Pump - for dual-fuel applications (locks
out 2nd stage compressor)
Not selectable at this time.
Installer run tests to check all output relays.
Tests confirm signals between thermostat/unit
are being sent/received. Stops system to run
system tests